3D Scanner Match - original native FreeCAD edit exercise License: CC0 1.0 Universal. https://creativecommons.org/publicdomain/zero/1.0/ Performed October 12, 2026 in FreeCAD 1.1.4, Windows x86_64 headless FreeCADCmd. Python 3.11.14 and OCCT 7.8.1; exact versions are recorded in file-check.json. WHAT THESE FILES ARE Original synthetic CAD, authored with Sketcher and PartDesign. No scan or STEP was reconstructed. Plate envelope: 80 x 50 x 6 mm. Coordinates: X -40..40, Y -25..25, Z 0..6. Central hole: global Z axis at X=Y=0, diameter 5 or 7 mm. Both sketches are fully constrained. History: PlateProfile -> PlatePad -> HoleProfile -> HolePocket. HoleProfile placement depends on PlatePad.Length. HolePocket is through all. This authored history is included in the FCStd files. THE ACTUAL TEN CHECKS Two builds, two STEP reimports, two fresh native opens, two diameter edits and two thickness edits. Native reopen used byte-identical copies with new filenames to avoid reuse of the in-memory build document. Outer bounds, one valid solid, analytic material volume, constrained sketches, dependencies and tip were checked. Reopened 5 mm -> 7 mm and reopened 7 mm -> 9 mm, then thickness 6 mm -> 8 mm. Those later edits were performed in memory and did not overwrite saved inputs. AN EDIT TASK FOR THESE EXACT NATIVE FILES In the reopened 5 mm fixture, HoleProfile constraint index 1 is named HoleDiameter. The tested API action is: doc.HoleProfile.setDatum(1, App.Units.Quantity('7 mm')) doc.recompute() doc.PlatePad.Length = 8.0 doc.recompute() The dependent hole sketch follows Z=8 and the pocket remains through all. The source script uses these same commands. No GUI usability workflow was tested. REPRODUCTION Requires a legal FreeCAD installation; no paid add-on is used in this check. In PowerShell, adjust the executable, script and fresh output paths: $env:SCANNER_NATIVE_OUTPUT = 'C:\your-files\native-result-fresh' & 'C:\FreeCAD\FreeCADCmd.exe' 'C:\your-files\freecad-parametric\reproduce.py' Use a new output folder. The script preserves previous output and its native reopen inputs. It never removes or replaces your source project. FILE NOTES AND LIMITS FCStd stores this authored FreeCAD history. The two STEP files were checked as geometry through Part.Shape reimport; these checks do not establish native feature-history transfer. Reproduction may change native UUIDs, timestamps and STEP metadata; compare checked geometry and dependencies, not reproduced hashes. Published hashes identify the exact downloadable bytes. No physical measurement, scanner benchmark, GUI test or independent geometric-kernel validation was done. Only these operations on these exact fixtures in FreeCAD 1.1.4 were checked.