3D Scanner Match - original native FreeCAD edit exercise
License: CC0 1.0 Universal. https://creativecommons.org/publicdomain/zero/1.0/
Performed October 12, 2026 in FreeCAD 1.1.4, Windows x86_64 headless FreeCADCmd.
Python 3.11.14 and OCCT 7.8.1; exact versions are recorded in file-check.json.

WHAT THESE FILES ARE
Original synthetic CAD, authored with Sketcher and PartDesign. No scan or STEP
was reconstructed. Plate envelope: 80 x 50 x 6 mm. Coordinates: X -40..40,
Y -25..25, Z 0..6. Central hole: global Z axis at X=Y=0, diameter 5 or 7 mm.
Both sketches are fully constrained. History: PlateProfile -> PlatePad ->
HoleProfile -> HolePocket. HoleProfile placement depends on PlatePad.Length.
HolePocket is through all. This authored history is included in the FCStd files.

THE ACTUAL TEN CHECKS
Two builds, two STEP reimports, two fresh native opens, two diameter edits and
two thickness edits. Native reopen used byte-identical copies with new filenames
to avoid reuse of the in-memory build document. Outer bounds, one valid solid,
analytic material volume, constrained sketches, dependencies and tip were checked.
Reopened 5 mm -> 7 mm and reopened 7 mm -> 9 mm, then thickness 6 mm -> 8 mm.
Those later edits were performed in memory and did not overwrite saved inputs.

AN EDIT TASK FOR THESE EXACT NATIVE FILES
In the reopened 5 mm fixture, HoleProfile constraint index 1 is named
HoleDiameter. The tested API action is:
doc.HoleProfile.setDatum(1, App.Units.Quantity('7 mm'))
doc.recompute()
doc.PlatePad.Length = 8.0
doc.recompute()
The dependent hole sketch follows Z=8 and the pocket remains through all.
The source script uses these same commands. No GUI usability workflow was tested.

REPRODUCTION
Requires a legal FreeCAD installation; no paid add-on is used in this check.
In PowerShell, adjust the executable, script and fresh output paths:
$env:SCANNER_NATIVE_OUTPUT = 'C:\your-files\native-result-fresh'
& 'C:\FreeCAD\FreeCADCmd.exe' 'C:\your-files\freecad-parametric\reproduce.py'
Use a new output folder. The script preserves previous output and its native
reopen inputs. It never removes or replaces your source project.

FILE NOTES AND LIMITS
FCStd stores this authored FreeCAD history. The two STEP files were checked
as geometry through Part.Shape reimport; these checks do not establish native
feature-history transfer. Reproduction may change native UUIDs, timestamps and
STEP metadata; compare checked geometry and dependencies, not reproduced hashes.
Published hashes identify the exact downloadable bytes. No physical measurement,
scanner benchmark, GUI test or independent geometric-kernel validation was done.
Only these operations on these exact fixtures in FreeCAD 1.1.4 were checked.